Automatic Fire Extinguishing Device
Automatic fire extinguishing device – long detection distance, large coverage area, high sensitivity, fast response. All-round monitoring, no blind spots, low false alarms. For convention centers, airports, train stations, malls, gyms, theaters, factories, hospitals, hotels.
Fujian Haijing Fire Fighting Equipment Co., Ltd. is one of the leading manufacturers and suppliers of automatic fire extinguishing device in China, also supports customized service. Please feel free to wholesale cheap automatic fire extinguishing device from our factory.
Product Introduction
Automatic Fire Extinguishing Device



Automatic Fire Extinguishing Device/20l-30L


How does it works?(step by step)
- Step 1 – Monitoring
The device scans the protected area. It uses one or more sensors:
UV (ultraviolet) flame detector – Sees the ultraviolet light that all fires emit. Very fast. Not fooled by sunlight (the sun's UV is blocked by the atmosphere).
IR (infrared) flame detector – Sees the infrared radiation from fire. Detects heat.
Video / image sensor – Uses a camera and software to recognize flame patterns.
Combination – Most devices use two or three technologies together for reliability.
- Step 2 – Fire detection
A fire starts. The sensor detects it. The device doesn't act immediately. It first verifies.
The device might:
Look again to confirm
Use a second sensor type to verify
Wait half a second to see if the signal continues
If the signal is real, the device declares a fire.
- Step 3 – Localization
The device calculates where the fire is. It uses the sensor data to find the direction – horizontal and vertical angle. It knows exactly where to aim.
- Step 4 – Aiming
Motors inside the device turn the nozzle or monitor. They point it directly at the fire. This takes 3 to 5 seconds.
- Step 5 – Discharge
The device opens a valve. Water or foam or gas flows from the supply pipe. It shoots out of the nozzle. Because the nozzle is aimed directly at the fire, the agent hits the fire immediately. The device may sweep the nozzle back and forth to ensure coverage.
- Step 6 – Extinguishment
The fire goes out. The device's sensors see that the flame is gone. It continues spraying for a few seconds to cool the area and prevent re-ignition.
- Step 7 – Shutdown and reset
The device closes the valve. It returns to its monitoring position. It waits for the next fire. If the fire re-ignites, the device will detect it and spray again.
All of this happens without a single person pushing a button.
Product Image





Company Information


FAQ
Q1: How is this different from a fire sprinkler system?
A sprinkler system waits for heat to break a glass bulb. That can take minutes. This device detects the flame itself in seconds. Then it aims directly at the fire, instead of spraying water everywhere. Less water damage, faster response.
Q2: What's the detection range?
Typically 40 to 50 meters for a small flame. That means one device covers a large area – hundreds or thousands of square meters.
Q3: How big of an area can one device protect?
Depends on ceiling height and obstructions. A typical device with 40m detection and 30m spray covers about 2,800 square meters. Compare to a sprinkler head that covers 12 square meters.
Contact Information
Send us your enquiry, we will reply In 24 Hours!
Siya Huang
WhatsApp/WeChat: +86 15102989485
E-mail: sales07@sajingfire.com
Add: Maosheng RD., Fumao Economic Zone, Nan'an City, Fujian, China, 362300
comparison of product parameters
| Products model | PS8/20 | PS8/30~40 | PS8/50 |
| Products material | Aluminum Alloy | ||
|
Rated W.P. (MPa) |
0.8 | 1.0 | |
| Working Pressure Range(MPa) | 0.5~1.6 | ||
|
Distance(m) |
55 | 60/65 | 70 |
|
Angle Of Horizontal Rotation(º) |
360 | ||
|
Angle Of Vertical Rotation(º) |
-60 ~ +70 | ||
|
Installation Mode |
Seating Arrangement |
||
|
Service Environment |
-10℃-+50℃ |
||
Hot Tags: automatic fire extinguishing device, China automatic fire extinguishing device manufacturers, suppliers, factory










