Piped FM200 Fire Suppression System
Three-in-one integrated design
Fully automatic operation
Proven and reliable technology
Reasonable structure, easy to operate
Systematic design
Fujian Haijing Fire Fighting Equipment Co., Ltd. is one of the leading manufacturers and suppliers of piped fm200 fire suppression system in China, also supports customized service. Please feel free to wholesale cheap piped fm200 fire suppression system from our factory.
The Piped FM200 Fire Suppression System is a fixed pipe network system that delivers FM200 gas through a network of pipes and nozzles into a protected room. Think of it as a sprinkler system – but instead of water, it discharges a clean gas that puts out a fire in seconds, leaves no residue, and won't ruin your expensive equipment.
FM200 is the brand name for HFC-227ea. It's been around for decades. It's safe for occupied spaces, safe for electronics, and it doesn't damage servers, circuit boards, or documents.
If you have a data center, a telecom room, a control room, a server farm, a museum archive, or a medical imaging suite – this is what you use. You don't use water there. Water destroys what you're trying to protect. FM200 doesn't.

Main Components


Bacis Technical Info
|
Model
|
Storage
Capacity
(L)
|
Filling
Pressure
(20°C)
|
Max.
Working
Pressure
(50°C)
|
Max. Single
Protected
Area
(㎡)
|
Storage
Room
Temperature
|
Discharge
Time
|
Automatic
Start
Delay
Time
|
Standard
|
|
QMQ4.2
|
92*188 | 37*37*102 | 192PCS | 476PCS |
-10°C ~ 50°C
|
≤10S
|
0~30S
Adjustable
|
GB25972-2010 |
Why Choose Our FM200 System?
We have been making fire suppression equipment since 1992. That's over 30 years. We've seen cheap systems fail. We've seen bad installation cause leaks. We've seen fake FM200 that doesn't put out fires.
Here's what we do differently:
- Real cylinders, real testing – Each cylinder is hydrostatically tested before it leaves. You get a test report with the serial number.
- Clear labeling – The nameplate has all the data an inspector wants. No guessing. No sticker that falls off after six months.
- We answer the phone – When your system needs service or you have a question about installation, you talk to a real person. Not a chatbot.
Company Information


Q&A
Pipeline type vs. cabinet type – which one do I need?
Pipeline type has cylinders in a separate room and pipes running to the protected area. Cabinet type has cylinders inside the protected room. Use pipeline for medium to large rooms (data halls, control rooms, power plants). Use cabinet for small rooms like server closets.
How does the pneumatic actuation device work?
It's the trigger on top of the valve. The fire panel sends a signal, the device fires, and the valve opens. For multiple cylinders, only one needs to be electric – the rest open by gas pressure from the first cylinder. Simple and reliable.
Is FM200 safe for people?
Yes at the designed concentration (typically 7-9%). It does not dangerously displace oxygen like CO2 does. But you still need to evacuate the room before discharge – that's why systems have a delay and warning alarms.
Contact Information
Send us your enquiry, we will reply In 24 Hours!
Siya
WhatsApp/WeChat: +86 15102989485
E-mail: sales07@sajingfire.com
Add: Maosheng RD., Fumao Economic Zone, Nan'an City, Fujian, China, 362300

Hot Tags: piped fm200 fire suppression system, China piped fm200 fire suppression system manufacturers, suppliers, factory