Foam in Air Bladder Tank
The SANJING FIRE foam bladder tank catalogue is a must-have for any fire protection system.
Fujian Haijing Fire Fighting Equipment Co., Ltd. is one of the leading manufacturers and suppliers of foam in air bladder tank in China, also supports customized service. Please feel free to wholesale cheap foam in air bladder tank from our factory.
Products Description
Foam tank (also known as foam concentrate tank or foam proportioning device) is the core equipment of fixed foam extinguishing system, which is mainly used to store foam extinguishing agent, and mix water and foam liquid in proportion to form extinguishing foam. It is widely used in high-risk areas such as oil depots, chemical plants, airports, and ships where flammable liquid fires occur.
The SANJING bladder tank foam extinguishing system is composed of a foam liquid pressure storage tank and a foam ratio mixer. It is a device that stores the foam liquid and mixes the foam liquid and water in a certain proportion..
When thefilling foam in air bladder tank pressure water flows through the equipment, the proportional mixer divides it in proportion, and a small part of the water enters the interlayer of the foam liquid storage tank with the capsule, squeezes the capsule, and replaces the same volume of the foam liquid with the rest of the main pipeline. The water is mixed into a certain proportion of foam mixture and delivered to the foam generating equipment.
Applicable scenarios
✅ Oil tank farm: fixed foam fire extinguishing system for large oil tanks
✅ Chemical plant: flammable liquid pipelines, reactor protection
✅ Airport/Hangar: Aviation Fuel Fire Protection
✅ Ship/offshore platform: engine room, cargo compartment foam fire fighting
✅ Garage/Warehouse: Large parking lot or logistics warehouse fire protection system
Parameter
|
Model specification |
Working pressure range (MPa) |
Storage tank volume (m3) |
Equipped with proportional mixer |
Flow range (L/s) |
mixing ratio(%) |
|
PHYML32/10(3%) |
0.6~1.2 |
1 |
PHY32 |
10~32 |
3~3.9 |
|
PHYML32/15(3%) |
1.5 |
||||
|
PHYML32/20(3%) |
2 |
||||
|
PHYM32/10(3%) |
1 |
||||
|
PHYM32/15(3%) |
1.5 |
||||
|
PHYM32/20(3%) |
2 |
||||
|
PHYM48/30(3%) |
3 |
PHY48 |
16~48 |
||
|
PHYM80/50(3%) |
5 |
PHY80 |
32~80 |
||
|
PHYM80/100(3%) |
10 |
Products Picture


Q&A
Q1: Can foam tank spray foam directly?
A1: Do not spray foam directly! The foam tank only provides foam mixture, and the foam generation equipment (such as foam gun and foam nozzle) needs to generate fire-fighting foam.
Q2: Where does the water source of foam tank come from?
A2: Fire water pump: draws water from the fire water pool or municipal pipeline network. Pressure water tank: Small systems may use pneumatic water supply.
Q3: How to adjust the mixing proportion of foam tank?
A3: Check the identification of the proportioner . Adjust the proportion by adjusting the valve or replacing the mixer orifice plate. Test whether the concentration of foam mixture meets the standard.
Q4: Does the foam tank system need to be tested regularly?
A4: Monthly inspection: liquid level, pressure gauge, valve flexibility. Annual testing: foam mixing ratio, spray performance. Every 3 years: Thoroughly clean the tank and inspect for corrosion. Test whether the concentration of foam mixture meets the standard.
Contact Information
Pauline
WhatsApp/WeChat: +86-13332933886
Email: manager@sanjingfire.com

Hot Tags: foam in air bladder tank, China foam in air bladder tank manufacturers, suppliers, factory, AFFF Tank, Vertical Bladder Tank, Foam Extinguishing, Foam Bladder Tank, Fire Foam Tank