Ductile Iron Air Vent Valve
Air Vent Valve is a type of valve designed to automatically release trapped air from or admit air into a fluid system, such as a pipeline or tank.
The valves are crucial for maintaining the efficiency and reliability of fluid conveyance systems by preventing air accumulation, which can cause operational issues like pressure surges, reduced flow rates, and potential damage to system components.
Fujian Haijing Fire Fighting Equipment Co., Ltd. is one of the leading manufacturers and suppliers of ductile iron air vent valve in China, also supports customized service. Please feel free to wholesale cheap ductile iron air vent valve from our factory.
Technical Pameters of Ductile Iron Air Vent Valve
Standard: NFPA 20
Connection: Threaded, NPT / BSP
Feature: Small orifice, vent air only
Temperature: Max 82°C, water
W. pressure: 175psi
Surface: FBE coating
| Inlet | Outlet | Orifice | Working Pressure (psi) |
| 1" NPT | 1/2" NPT | 1/16" | 175 |
Image Details of Ductile Iron Air Vent Valve




Key Functions of Ductile Iron Air Vent Valve?
1. Air Release: Automatically expels trapped air from the system to prevent air locks and ensure smooth fluid flow.
2. Air Admission: Allows air to enter the system during draining or when the fluid level drops, preventing vacuum formation and potential damage.
3. Pressure Regulation: Helps maintain stable pressure by managing air within the system, reducing the risk of water hammer and other pressure-related issues.
Company Information



FAQ
Q: How can I identify if my system needs an Ductile Iron Air Vent Valve?
A: To determine if your system needs an air vent valve, consider the following criteria and symptoms:
Criteria for Installation:
Wet Pipe Sprinkler Systems: Requirement: NFPA 13 requires a single air vent on each wet pipe system utilizing metallic pipe.
Methods: Options include manual valves, automatic air vents, remote inspector's test valves, or other approved means.
Location: The air vent should be located at an accessible point near a high point in the system where the greatest volume of trapped air is vented.
Q: How often should I check my Ductile Iron Air Vent Valve?
A: An initial inspection interval of no longer than 12 months is recommended. This ensures that the valve is functioning correctly and any potential issues are identified early.