Automatic Wet Alarm Valve Sprinkler System
video
Automatic Wet Alarm Valve Sprinkler System

Automatic Wet Alarm Valve Sprinkler System

A wet alarm valve is a type of alarm check valve in a wet sprinkler system that uses water flow to trigger audible alarms, such as a water motor gong or electric alarm.
It is a one-way valve that prevents water from flowing back into the supply line, and when water flows through it due to a sprinkler activating, it activates a local waterflow alarm.

Fujian Haijing Fire Fighting Equipment Co., Ltd. is one of the leading manufacturers and suppliers of automatic wet alarm valve sprinkler system in China, also supports customized service. Please feel free to wholesale cheap automatic wet alarm valve sprinkler system from our factory.

 

 

Products Description of Automatic Wet Alarm Valve Sprinkler System

 

Material: Ductile Cast Iron

Size Range: From 3 Inch (DN80) to 12 Inch (DN300)

Body Type: Flange x Flange

Working Pressure: 16Bar (232psi)

Flange Standard: BS or ANSI

With alarm gong, retard chamber, pressure gauge

23

1product-1200-1200

product-540-540

 

How Automatic Wet Alarm Valve Sprinkler System Works

 

1. One-Way Flow:

The valve is designed to allow water to flow into the sprinkler system but prevents it from flowing back out into the water supply.

 

2. Water Flow Activation:

When a sprinkler activates, the water flow opens a flap or clapper in the valve.

 

3. Alarm Activation:

This water flow also operates a trim assembly connected to the valve, which includes a delay device to prevent false alarms from minor pressure fluctuations.

 

4. Alarm Sounding:

The water then actuates a water motor gong (a mechanically powered alarm) or sends a signal to an electrical alarm system, which sounds an audible alarm.

 

Company Information

Factory Introduction

Workshop

ISO-2

FAQ

 

Q: How does the Automatic Wet Alarm Valve Sprinkler System prevent false alarms from pressure surges?
A: A bypass line with a restrictor and a retard chamber delays the alarm signal; transient pressure spikes equalise across the clapper without lifting it, so only sustained flow (≥1 sprinkler) triggers the bell.

 

Q: Can one wet alarm valve serve multiple floors?

A: Yes-provided the floor area does not exceed the valve's rated flow (common sizes 500–2 000 L/min) and static pressure at the most remote sprinkler remains ≥0.5 bar above the valve set-point

 

contact Information

 

Send us your enquiry, we will reply In 24 Hours!

WhatsApp/WeChat: +86 18359194029

E-mail: sales03@sanjingfire.com
Add: Maosheng RD., Fumao Economic Zone, Nan'an City, Fujian, China, 362300