A dry pipe fire alarm valve is a latching, differential-style control valve that holds back water in a dry pipe sprinkler system until a fire activates a sprinkler head.
The system's pipes are filled with compressed air or nitrogen, not water, which prevents freezing in unheated areas.
When a sprinkler opens, the air pressure drops, allowing the water pressure to overcome the differential and open the valve, flooding the system and extinguishing the fire.

Fujian Haijing Fire Fighting Equipment Co., Ltd. is one of the leading manufacturers and suppliers of dry pipe sprinkler fire alarm valve in China, also supports customized service. Please feel free to wholesale cheap dry pipe sprinkler fire alarm valve from our factory.

 

Specifications of Dry Pipe Sprinkler Fire Alarm Valve 

Alarm Check Valve (Dry Type) Basic Technical Info

Model

ZSFC80

ZSFC150

ZSFC200

Inside nominal diameter(mm)

80

150

200

Rated working pressure (MPa)

1.2MPa

Sealed test (MPa)

2.4MPa

Strength test (MPa)

4.8MPa

Alarm flow (L/min)

"15

Q<170 @1.6MPa"

Retard alarm time(s)

5~90

Alarm Bell Start Pressure(MPa)

≤0.035

Friction Resistance(MPa)

≤0.02

"Height of alarm valve(mm)

375

450

576

"Outside diameter of flange (mm)"

220

285

340

"Outside diameter of flange screw hole (mm)"

180

240

295

"Diameter of screw hole (mm)

8

Quantity of screw hole

18

22

22

product-1200-12001

1

p3

 

When a Dry Pipe Sprinkler Fire Alarm Valve trips the accelerator?

 

The Accelerator automatically adjusts to both small and slow changes in sys- tem pressure but trips when there is a rapid and steady drop in pressure (such as will occur when a sprinkler operates). Upon tripping, the Accelera- tor transmits system air pressure to the intermediate chamber of the dry pipe valve.

 

Company Information

Factory Introduction

Workshop

ISO-2

 

FAQ

 

Q: How much air pressure must be maintained?
A:
Normal system air is 40 psi (2.8 bar) with a 5:1 differential to water supply; a low-air supervisory switch signals at 30 psi (≈ 10 psi drop) to give a pre-trouble warning .

 

Q: How is the Dry Pipe Sprinkler Fire Alarm Valve reset after activation?
A:
Close the supply control valve, drain the system, restore air pressure to above the trip point, then open the external-reset knob (or remove the face-plate on older models) to latch the clapper closed; finally reopen the water supply

 

Contact Information

 

Send us your enquiry, we will reply In 24 Hours!

WhatsApp/WeChat: +86 18359194029

E-mail: sales03@sanjingfire.com
Add: Maosheng RD., Fumao Economic Zone, Nan'an City, Fujian, China, 362300

 

<br />

product-1353-391

 

 

product-622-405

Hot Tags: dry pipe sprinkler fire alarm valve, China dry pipe sprinkler fire alarm valve manufacturers, suppliers, factory, Dry Alarm Valve, Dry Pipe Valve, Pre Action Alarm Valve

(0/10)

clearall