
Water Curtain Sprinkler
The Water Mist Sprinkler is the main element of the water mist system. The pressurized water is inside it. After collision, rotation, and stirring, it sprays tiny water droplets, which has better cooling, suffocation and electrical insulation. It is widely used in industrial sites such as flammable, combustible gas, liquid processing and storage.
Fujian Haijing Fire Fighting Equipment Co., Ltd. is one of the leading manufacturers and suppliers of water curtain sprinkler in China, also supports customized service. Please feel free to wholesale cheap water curtain sprinkler from our factory.
What Is a Water Curtain Fire Sprinkler?
It's not a standard fire sprinkler. Standard sprinklers put water on a fire to put it out. A water curtain sprinkler puts water in the air – in the shape of a curtain – to stop a fire from getting through.
Think of it as a water wall. A vertical sheet of water that blocks heat, smoke, and flames from passing from one side to the other. It doesn't necessarily put out the fire. It contains the fire. Keeps it where it started. Protects the other side.
The nozzle takes pressurized water and sprays it out in a fan shape – usually 140° or 160° wide . The water forms a continuous curtain at a specific width and thickness . That curtain absorbs heat, blocks radiant energy, and stops smoke from moving through openings.
These are open nozzles. No glass bulb. No fusible link. They don't activate by heat. They're connected to a deluge valve that opens when a fire detection system or manual release is triggered . When the valve opens, all the water curtain nozzles on that system discharge at once.

|
Model
|
Nominal Diameter
(mm)
|
Connection Thread
(mm)
|
Flow Coefficient (K) |
Spray Angle | Surface Color |
| ZSTWC | DN15 | R1/2 | 21 | 60° | Chrome /Brass |
| DN20 | R3/4 | 54 | 90° | ||
| ZSTWB | DN15 | R1/2 | 16 | 90° | Chrome |
| DN20 | R3/4 | 34 | |||
| ZSTWA | DN15 | R1/2 | 42 | 140° | Chrome |
| ZSTMB | DN15 | R1/2 | 45 | 160° | Chrome |
| DN20 | R3/4 | 90 |
Where Do You Use Water Curtain Sprinklers?
- Building openings. Doors, windows, and other openings in fire-rated walls. If you have a large opening that can't be closed with a fire door, a water curtain is an approved alternative . It stops fire from passing through the opening.
- Stages and theaters. The proscenium opening – the big arch above the stage. A water curtain separates the stage (where the fire is) from the audience seating area . Keeps the audience safe while the stage burns.
- Atriums. Large open spaces in buildings. Water curtains protect the glass walls around atriums – keeping a fire on one floor from spreading to the floor above .
- Industrial facilities. Large factories, workshops, and warehouses . Between different fire zones. Between storage areas and processing areas.
- Adjacent buildings. Where two buildings are close together and a fire in one could spread to the other. A water curtain on the outside wall of one building protects the other.
- Refuge floors. In super-tall buildings, refuge floors are safe areas where people can wait during a fire. Water curtains protect the openings on these floors from fire and smoke from the floors below .
The common thread: places where you need to stop fire spread but can't use a physical barrier – a wall, a fire door, or a fire shutter.
Testing and Maintenance
Test quarterly: Activate the deluge valve. Verify all nozzles are flowing. Check for blocked or damaged nozzles.
Inspect annually: Check nozzle alignment. Make sure they're still aimed correctly. Look for corrosion, damage, or debris.
Clean as needed: Debris can clog the small nozzle openings. Clean with a soft brush. Don't use a metal tool – it will scratch the brass.
Replace damaged nozzles: If a nozzle is bent, corroded, or clogged – replace it. Water curtains depend on a precise spray pattern. Damaged nozzles create gaps in the curtain.
Poducts Picture




Company Information


FAQ
Q1: What's the difference between a water curtain sprinkler and a standard fire sprinkler?
A standard sprinkler puts water on a fire to extinguish it. A water curtain sprinkler creates a vertical wall of water to stop fire, heat, and smoke from passing through an opening. It doesn't put out the fire – it contains it.
Q2: Where are water curtain sprinklers used?
On openings in fire-rated walls – doors, windows, stage prosceniums, atriums. Also between buildings, in industrial facilities, and on refuge floors in super-tall buildings. Anywhere you need to stop fire spread but can't use a physical barrier.
Q3: Are water curtain sprinklers heat-activated like regular sprinklers?
Most are open – no glass bulb. They're connected to a deluge valve that opens when a fire detection system or manual release is triggered. When the valve opens, all nozzles discharge at once. Some are closed (heat-activated), but open type is standard for water curtains.
Contact Information
Send us your enquiry, we will reply In 24 Hours!
Siya Huang
WhatsApp/WeChat: +86 15102989485
E-mail: sales07@sajingfire.com
Add: Maosheng RD., Fumao Economic Zone, Nan'an City, Fujian, China, 362300
Hot Tags: water curtain sprinkler, China water curtain sprinkler manufacturers, suppliers, factory







