Flange Wet Alarm Check Valve

Flange Wet Alarm Check Valve

Alarm check valve – dual-purpose for wet pipe sprinkler systems. Prevents reverse water flow, triggers water motor gong. Retard chamber stops false alarms from pressure changes.

Fujian Haijing Fire Fighting Equipment Co., Ltd. is one of the leading manufacturers and suppliers of flange wet alarm check valve in China, also supports customized service. Please feel free to wholesale cheap flange wet alarm check valve from our factory.

 

Products Description

Automatic Wet Alarm Valve Sprinkler System
Alarm Check Valve

Alarm Check Valve is core element in wet pipe fire sprinkler systems.It serves a dual purpose which prevents a reverse flow of water (non-return),also provides for the use of the water motor gong. Meanwhile,in the event of variable pressure condition,false alarm is prevented with provision of retard chamber at the external bypass.

Feature:

Material                                                      Ductile Cast Iron Body,Brass Seat

Nominal Diameter                                    80-250mm/3inch-10inch

Rated Working Pressure                          1.6mpa

Sealed Test                                                3.2mpa

Strength Test                                             6.4mpa

Alarm Flow (L/Min)                                  15<q<60

Retard Alarm Time (S)                              5~90

Friction Resistance                                  ≤0.035mpa

Structure                                                     Waterpower Check Valve

Surface Finishing                                      Painting Red

Use Range                                                  Fire Sprinkler System

10

product-602-169

 

 

Where Do You Use an Alarm Check Valve?

 

Any wet pipe sprinkler system needs one. That includes:

  • Office buildings
  • Hotels
  • Shopping malls
  • Hospitals
  • Schools
  • Apartment buildings
  • Parking garages
  • Factories and warehouses
  • Data centers (in non-computer areas)
  • Any building with automatic sprinklers

One alarm check valve per sprinkler system. Big buildings may have multiple systems – one per floor or per fire zone – and each needs its own valve.

The valve is usually in a mechanical room, near where the water supply enters the building. It's often installed next to the fire pump or the main water shutoff valve. You'll see pipes going in and out, a small retard chamber on the side, and a trim set with gauges, test valves, and a connection to the water motor gong.

It's not a pretty piece of equipment. It's heavy, cast metal, usually painted red. But it's the heart of the sprinkler system. No valve, no alarm. No alarm, no one knows there's a fire until the water comes through the ceiling.

 

Company Information

 

 

 

 

Factory Introduction

Workshop

why choose us
 
10

why choose our products

 
  • Dual purpose – Non-return + alarm trigger. Simplifies system design.
  • Retard chamber – Stops false alarms from pressure surges. Adjustable delay.
  • Ductile iron body – Stronger than gray iron. Resists water hammer and freezing.
  • EPDM clapper – Flexible, durable, seals tight.
  • Complete trim set – Gauges, test valves, alarm shutoff. Factory installed. Ready to mount.
  • Water motor gong – Available. Matched flow for reliable operation.
  • Stocked sizes – DN80 to DN250. Flanges to EN or BS.
  • We answer – Email or WhatsApp. Real people.

 

 

Why Choose Our Alarm Check Valves?

 

  • Dual purpose – Non-return and alarm trigger in one valve. Simplifies system design.
  • Retard chamber included – Stops false alarms from pressure surges. Adjustable delay.
  • Ductile iron body – Stronger than gray iron. Won't crack from water hammer or freezing.
  • Corrosion-resistant clapper – EPDM rubber face. Flexible, durable, seals tight.
  • Complete trim set – Gauges, test valves, alarm shutoff – all installed at the factory. Ready to mount.
  • Water motor gong available – We supply the matching gong. Matched flow rates for reliable operation.
  • Stocked sizes – DN80, DN100, DN125, DN150, DN200, DN250. Flanges to EN, BS.
  • We answer questions – Need help sizing or troubleshooting? Email or WhatsApp us. Real people reply.

 

FAQ

 

Q1: What's the difference between an alarm check valve and a regular check valve?

A regular check valve only stops reverse flow. An alarm check valve does that – plus it sends water to a water motor gong when flow happens. The retard chamber prevents false alarms from pressure surges.

Q2: Where is the alarm check valve installed?

In the mechanical room, on the main water supply pipe to the sprinkler system. Installed horizontally. The water motor gong mounts on the outside wall.

Q3: How does the retard chamber prevent false alarms?

It delays the alarm by 30 to 60 seconds. Short pressure surges don't have enough volume to fill the chamber. Only steady, continuous flow – from a real sprinkler opening – fills the chamber and triggers the gong.

 

Contact Us

 

Send us your enquiry, we will reply In 24 Hours!
Siya Huang
WhatsApp/WeChat: +86 15102989485
E-mail: sales07@sajingfire.com
Add: Maosheng RD., Fumao Economic Zone, Nan'an City, Fujian, China, 362300

Hot Tags: flange wet alarm check valve, China flange wet alarm check valve manufacturers, suppliers, factory, Alarm Check Valve, Fire Alarm Check Valve, Groove Wet Alarm Valve, Sprinkler Alarm Check Valve, Valve and System, Wet Alarm Valve

(0/10)

clearall