Dry Type Alarm Check Valve

Dry Type Alarm Check Valve

The dry alarm valve is an important component of the dry automatic water spray system. The dry automatic sprinkier systemis designed to meet the needs of installing automatic sprinkler systems in cold and high-temperature places. It is a closed system which developed on the basis of the wet system. The dry system adopts a closed fire sprinkler. Dueto in the pipe network at the system side is the pressure gas (compressed air or nitrogen gas), so the phenomenon of thepressurized water frozen or evaporation when the wet system is used can be avoided.

Fujian Haijing Fire Fighting Equipment Co., Ltd. is one of the leading manufacturers and suppliers of dry type alarm check valve in China, also supports customized service. Please feel free to wholesale cheap dry type alarm check valve from our factory.

 

 

Products Description

 

 
Product Introduction
 
product-400-403
 
product-289-213
 
-ZSFC
 

Dry type alarm valve is an important component of dry automatic sprinkler fire extinguishing system, mainly composed of dry valve, hydraulic alarm bell, pressure switch, air pressure maintenance device, etc. Dry automatic sprinkler system is a closed system developed on the basis of wet system to meet the needs of installing automatic sprinkler system in cold and high temperature places. The dry system adopts a closed nozzle and is usually filled with pressurized gas (compressed air or nitrogen) in the system side pipeline network. When a fire occurs in the protected area and the temperature rises, the nozzle will sense the temperature and release pressure gas, causing a decrease in pressure on the system pipe network side. The pressure water on the supply side will open the dry alarm valve, and the system will achieve water spray fire extinguishing. At the same time, a small portion of the water flows through the alarm port towards the hydraulic alarm bell and pressure switch, emitting alarm sounds and electrical signals. Dry system, which is filled with pressurized gas instead of water in the same state pipeline, is suitable for fire protection in places where there is a risk of freezing and water in the pipeline may vaporize due to high ambient temperature. It is commonly used in places where the ambient temperature is below 4 ℃ or above 70 ℃.

 

 

The core advantages of dry alarm valves

 

(1) Anti freezing and leak proof, suitable for low-temperature environments
No water retention: The pipeline behind the valve is filled with compressed air to avoid pipeline freezing and cracking in cold regions such as northern garages and cold storage.
Zero leakage risk: Under normal conditions, there is no static water pressure in the pipeline, which prevents leakage from damaging building decoration.
(2) Quick response and high fire extinguishing efficiency
Pneumatic linkage: After the nozzle ruptures, the sudden drop in air pressure triggers the valve to open instantly, and the delay for water flow to fill the pipeline is ≤ 60 seconds
Double alarm: mechanical pressure switch+hydraulic alarm bell, ensuring that the fire signal is transmitted to the control room.
(3) Easy maintenance and cost optimization
Low water loss: Only inject water during a fire, with no water consumption for daily hydraulic testing, significantly saving water.
Convenient maintenance: System reset does not require emptying the entire pipeline network, and compressed air replenishment is fast.
(4) Strong system reliability
Anti misoperation: Air pressure monitoring can distinguish between nozzle rupture and minor leakage.
Suitable for a wide temperature range: stable operation in environments ranging from -40 ℃ to 70 ℃.

 

 

Typical application scenarios

 

1.Low temperature environment: underground parking lot (winter in the north), cold chain logistics center, ski equipment room.
2.Temporary buildings: temporary buildings on construction sites, exhibition halls (areas that require heating to be turned off during winter).
3.Special places: wooden ancient buildings (to reduce the risk of water leakage), high-altitude curtain wall cleaning equipment layer.

 

 

product-529-155

 

Company Information

 

product-1280-720

cases

 

 

 

Q&A

 

Q: What are the requirements for installation? ​​

A: Location: Indoor installation , located near the entrance of the protective zone. The valve body needs to be installed horizontally, with the direction of the arrow aligned with the water flow. Pipeline: The slope of the pipeline network should be ≥ 0.02, and a drainage valve should be installed at the low point to prevent water accumulation and freezing cracks. The inflation pipeline needs to be equipped with a filter .

 